Widok
Sort type
Per page
Additional calibration curve stored in the sensor (selectable via display)

Additional calibration curve stored in the sensor (selectable via display)

Z695 5011

On order

Product prices will become visible after signing in.

Certificate of origin

Certificate of origin

Z695 5012

On order

Product prices will become visible after signing in.

Closing cap for measuring section in aluminium

Closing cap for measuring section in aluminium

0190 0001

On order

Product prices will become visible after signing in.

Closing cap for measuring section stainless steel 1.4571

Closing cap for measuring section stainless steel 1.4571

0190 0002

On order

Product prices will become visible after signing in.

Compact inline fow sensor

Compact inline fow sensor

0695 5250
- m³/h, l/min (1000 mbar, 20°C) w przypadku spręż.pow. lub Nm³/h, Nl/min (1013 mbar, 0°C) w przypadku innych gazów
- m³/h, m³/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min, g/s, lb/min, lb/h
- kalorymetryczny, Pozycja montażu: dowolna
- powietrze, gazy
- ± 1.5 % wart.pom. ± 0.3 % pełnej skali; na życzenie ± 1.0 % wart.pom. ± 0.3 % pełnej skali ± 6.0 % wart.pom. ± 0.5 % pełnej skali
- -30...80 °C
- 0…16 bar, dokładność 1%
- 4...20 mA dla m³/h lub l/min
- Opcjonalne: Modbus RTU, Ethernet, PoE, M-Bus.
- impuls na m³ lub na litr separacja galwaniczna. Wartości impulsu regulowane poprzez wyświetlacz. Alternatywnie. wyjście impulsowe może być używane jako przekaźnik alarmu
- 18...36 VDC, 5 W
- < 500 Ω
- Obudowa: poliwęglan (IP 65), Odcinek pomiarowy: aluminium,

Available

Product prices will become visible after signing in.

Ethernet connection cable length 10 m, M12 plug x coded (8 pin) to RJ 45 plug

Ethernet connection cable length 10 m, M12 plug x coded (8 pin) to RJ 45 plug

0553 2504

On order

Product prices will become visible after signing in.

Flow direction switch VA 409

Flow direction switch VA 409

0695 0409
- < 0.1 m/s w odniesieniu do 20°C i 1000 mbar
- 2 LEDs
- Kalorymetryczny, pomiar kalorymetryczny
- powietrze, gazy
- 0...50°C rurka sondy, -20...70°C obudowa
- do 16 bar
- 24 VDC, 40 mA
- max. 80 mA up do 24 VDC
- 54
- zgod. z DIN EN 61326
- 2 x M12, 5-biegunowe, wtyczka A i wtyczka B, 2 x U max. 60 VDC, l max 0,5 A (normalnie zamknięty); na życzenie: normalnie otwarty
- stal nierdzewna, 1,4301, długość 160 mm, Ø 10 mm, pierścień zabezp. Ø 11.5 mm, dłuższe sondy na życzenie
- G 1/2“
- 65 mm

On order

Product prices will become visible after signing in.

Flow meter VA 520 with integrated measuring section, (R 1 1/2“ DN 40)

Flow meter VA 520 with integrated measuring section, (R 1 1/2“ DN 40)

0695 0524
- Bez kołnierza
- m³/h, l/min (1000 mbar, 20°C) w przypadku spręż.pow. lub Nm³/h, Nl/min (1013 mbar, 0°C) w przypadku innych gazów
- m³/h, m³/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min
- kalorymetryczny, pomiar kalorymetryczny
- powietrze, gazy
- powietrze, azot, argon, podtlenek azotu, CO2, tlen
- ± 1.5 % wart.pom. ± 0.3 % pełnej skali; na życzenie ± 1.0 % wart.pom. ± 0.3 % pełnej skali
- -30...80 °C
- do 16 bar, opcjonalnie do PN 40
- 4...20 mA dla m³/h resp. l/min
- interfejs RS 485, Modbus-RTU, M-Bus (opcja)
- impuls na m³ lub na litr separacja galwaniczna
- 18...36 VDC, 5 W
- < 500 Ω
- Obudowa: poliwęglan, Odcinek pomiarowy: stal nierdzewna, 1.4301 lub 1.4404, Kołnierz: Kołnierz wspawany zgodnie z DIN EN 1092- 1, na żądanie inne typy kołnierzy

Available

Product prices will become visible after signing in.

Flow meter VA 570 with integrated 2" measuring section

Flow meter VA 570 with integrated 2" measuring section

0695 0575
- Bez kołnierza
- 0.1...92,7 Nm/s, wersja standard* 0.1...185 Nm/s, wersja max.* 0.1...224 Nm/s, wersja high speed*
- ± 1.5 % m.v. ± 0.3 % f.s. na życzenie ± 1.0 % of m.v. ± 0.3 % f.s.
- t90 < 3 s
- -40...180 °C rurka sondy -40...70°C wyświetlacz -40...120°C dla wersji ATEX
- 500 Ohm
- 67
- G 1/2“ ISO 228, NPT 1/2“, R 1/2“, PT 1/2“
- 16 bar; wersja specjalna 40 bar
- 18...36 VDC, 5 W
- ATEX II 2G Ex d IIC T4, DVGW
- W odniesieniu do temperatury otoczenia 22°C ± 2°C, ciśnienie w instalacji 6 bar
- Możliwość regulacji przez urządzenia zewnętrzne DS 400, DS 500
- 0.25 % wartości zmierzonej przy prawidłowym montażu (przyrząd montażowy, położenie, odcinek wlotowy)
- Termiczny czujnik przepływu masowego PT 45, który mierzy efekt schładzania przez przepływający gaz. Temperatura medium mierzona jest za pomocą PT100. Dodatkowa kompensacja ciśnienia i temperatury nie jest konieczna.
- Nm³/h, Nm³/min, Nl/min, l/s, ft/min, cfm, kg/h, kg/min, typ gazu, średnica wew., warunki referencyjne °C/°F, mbar/hPa, korekta punktu zero, ograniczenie objętości przepływu nieszczelności, skalowanie wyjścia analogowego 4...20 mA, impuls/alarm, kody b
- 4...20 mA czynny (nie izolowany galw.), Opcjonalne: 2 x 4...20 mA wyjścia izolowane galw.
- Modbus RTU, Opcjonalnie: Ethernet , Modbus/TCP), Profibus DP, HART-Protocol, Profinet,
- impuls izolowany galw. (waga impulsu ustalana dowolnie)
- Obudowa – odlew aluminiowy, rurka sondy ze stali nierdzewnej 1,4571

On order

Product prices will become visible after signing in.

Recalibration and 5 point precision calibration of volume fow sensors
VA 520/570 with ISO certificate

Recalibration and 5 point precision calibration of volume fow sensors VA 520/570 with ISO

0695 3332

On order

Product prices will become visible after signing in.

VA 500 meter in basic version:
Standard (92,7 m/s), probe length 220 mm, without display

VA 500 meter in basic version: Standard (92,7 m/s), probe length 220 mm, without display

0695 5001
- m³/h, l/min (1000 mbar, 20°C) w przypadku spręż.pow. lub Nm³/h, Nl/min (1013 mbar, 0°C) w przypadku innych gazów
- m³/h, m³/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min, g/s, lb/min, lb/h
- średnica do kalkulacji przepływu objętościo-wego zerowanie licznika
- termiczny czujnik masowy
- powietrze, gazy
- Powietrze (także w próżni), azot, argon, pod-tlenek azotu, CO2, tlen
- ± 1.5 % wart.pom. ± 0.3 % pełnej skali; na życzenie:± 1.0 % wart.pom. ± 0.3 % pełnej skali
- -30...110°C rurka sondy; -20...85°C z czujnikiem ciśnienia; -20...70°C obudowa
- -1…150 bar (dla ciśnienia >10 bar - konieczna dodatkowa ochrona dostępna w opcji)
- interfejs RS 485, Modbus-RTU; opcjonalnie: M-Bus, Ethernet PoE
- 4...20 mA dla m³/h lub l/min
- 1 impuls na m³ lub na litr izolacji elektrycznej. Na wyświetlaczu można ustawić wagę impulsu. Alternatywnie wyjście impulsowe można wy-korzystać jako alarm.
- 18...36 VDC, 5 W
- < 500 Ω
- poliwęglan (IP 65)
- stal nierdzewna 1.4301; długość montażowa 220 mm, Ø 10 mm
- G 1/2“
- 65 mm
- dowolna

On order

Product prices will become visible after signing in.

VA 521 - Compact inline flow sensor for compressed air and other types of gas

VA 521 - Compact inline flow sensor for compressed air and other types of gas

0696 0521
- Powietrze, Gazy
- Powietrze, azot, argon, CO2, tlen
- Standard: ± 1.5% of m.v. ± 0.3 % f.s. Opcjonalnie: ± 1% m.v. ± 0.3% f.s
- Poliwęglan IP65, Aluminium / Stal nierdzewna 316L
- -30…80 °C, -20...80 °C z czujnikiem ciśnienia
- Do 16 bar, opcjonalnie do 40 bar
- 67
- 1/2", 3/4", 1", 1 1/4", 1 1/2", 2" G lub NPT
- 18…36 VDC, 5 W < 500 Ω
- Interfejs RS 485, (Modbus-RTU), Opcjonalnie: M-Bus, interfejs Ethernet lub PoE
- 4…20 mA na m³/h albo l/min
- m³/h, m³/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min, g/s, lb/min, lb/h

On order

Product prices will become visible after signing in.

VA 550 Flow meter, measuring head in robuste aluminium die casting

VA 550 Flow meter, measuring head in robuste aluminium die casting

0695 0550
- do 50 Nm/s, wersja niskoprzepływowa | do 92,7 Nm/s, wersja standard | do 185 Nm/s, wersja max. | do 224 Nm/s, wersja high speed. |
- ± 1.5 % m.v. ± 0.3 % f.s. | Na życzenie - ± 1.0 % of m.v. ± 0.3 % f.s.
- w odniesieniu do temperatury otoczenia 22°C ± 2°C, ciśnienie w układzie 6 bar
- 0,25% w. m. w przypadku prawidłowego montażu (m.in. pozycja, sekcja wlot.)
- czujnik termiczny, czujnik przepływu masowego
- t90 < 3 s
- -40...180 °C rurka sondy | -40...70°C wyświetlacz | -40...120°C dla wersji ATEX
- 500 Ohm
- 67
- G 1/2“ ISO 228, NPT 1/2“, R 1/2“, PT 1/2“
- -1 ÷ 50 bar; wersja specjalna 100 bar (dla certyfikacji DVGW max. 16 bar)
- 18...36 VDC, 5 W
- ATEX II 2G Ex db IIC T4 Gb, ATEX II 2D Ex tb IIC T90 °C, Db, DVGW
- 4…20 mA (nieizolowane elektrycznie)
- Opcjonalne: 2 x 4...20 mA aktywne, Modbus TCP, HART, Profibus DP, Profinet, M-Bus
- RS 485 (Modbus-RTU)
- Obudowa – odlew aluminiowy, rurka sondy ze stali nierdzewnej 1,4571

On order

Product prices will become visible after signing in.

VD 500 Flow meter for FAD measurement

VD 500 Flow meter for FAD measurement

0690 5001
- 1:10
- powietrze, gazy nieagresywne
- ± 1,5 % mv. ± 0,3 % fs. (20…224 m/s)
- ciśnienie różnicowe
- T 99: < 1 sek.
- -30...+180°C
- maks. 20 barów
- -30...+70°C
- G ½”, ISO228
- 18…36 V DC, 5W
- Standard: RS 485 (Modbus-RTU), 4…20mA, impuls Opcja: Interfejs Ethernet (PoE), M-Bus

On order

Product prices will become visible after signing in.